Admin 19 Apr · asked in CFM and air
Answered

What PSI should I run to clean weld scale on structural beams without warping thin metal in a small shop?

Thin structural beams panels warp when I blast hard. Media is silicon carbide, nozzle is #4 (1/4"). Need a safer pressure window for coating with zinc-rich primer. Looking…

CFM and air

Top answer

On thin structural beams, begin near the low end of 80 PSI and increase only until you clean weld scale cleanly. Hot spots and long dwell times warp…

0 found this helpful 1 answer
Answer
Admin 18 Apr · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 494)?

Pot holds pressure at rest, then falls once I pull the trigger on welded fabrications. Setup uses a #4 (1/4") nozzle and a compressor advertised at 50 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 50 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 17 Apr · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 488)?

Planning air for a contractor pot. Target pressure is 80 PSI with a #4 (1/4") nozzle while I prep for powder coat on farm equipment. Current compressor is…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 100 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 15 Apr · asked in CFM and air
Answered

What PSI should I run to strip paint on stainless steel without warping thin metal in a small shop?

Thin stainless steel panels warp when I blast hard. Media is aluminum oxide, nozzle is #4 (1/4"). Need a safer pressure window for coating with powder coat. Looking…

CFM and air

Top answer

On thin stainless steel, begin near the low end of 80 PSI and increase only until you strip paint cleanly. Hot spots and long dwell times warp panels…

0 found this helpful 1 answer
Answer
Admin 14 Apr · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 476)?

Pot holds pressure at rest, then falls once I pull the trigger on alloy wheels. Setup uses a #4 (1/4") nozzle and a compressor advertised at 25 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 25 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 13 Apr · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 470)?

Planning air for a vacuum blast unit. Target pressure is 80 PSI with a #4 (1/4") nozzle while I peen for fatigue life on steel tanks. Current compressor…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 50 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 12 Apr · asked in CFM and air
Answered

What PSI should I run to prep for powder coat on cast iron without warping thin metal in a small shop?

Thin cast iron panels warp when I blast hard. Media is silicon carbide, nozzle is #4 (1/4"). Need a safer pressure window for coating with clear coat. Looking…

CFM and air

Top answer

On thin cast iron, begin near the low end of 80 PSI and increase only until you prep for powder coat cleanly. Hot spots and long dwell times…

0 found this helpful 1 answer
Answer
Admin 10 Apr · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 458)?

Pot holds pressure at rest, then falls once I pull the trigger on exhaust manifolds. Setup uses a #4 (1/4") nozzle and a compressor advertised at 15 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 15 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 9 Apr · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 452)?

Planning air for a blast room. Target pressure is 80 PSI with a #4 (1/4") nozzle while I clean weld scale on sheet metal panels. Current compressor is…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 25 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 8 Apr · asked in CFM and air
Answered

What PSI should I run to peen for fatigue life on automotive frames without warping thin metal in a small shop?

Thin automotive frames panels warp when I blast hard. Media is aluminum oxide, nozzle is #4 (1/4"). Need a safer pressure window for coating with paint strip. Looking…

CFM and air

Top answer

On thin automotive frames, begin near the low end of 80 PSI and increase only until you peen for fatigue life cleanly. Hot spots and long dwell times…

0 found this helpful 1 answer
Answer
Admin 7 Apr · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 440)?

Pot holds pressure at rest, then falls once I pull the trigger on structural beams. Setup uses a #4 (1/4") nozzle and a compressor advertised at 100 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 100 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 5 Apr · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 434)?

Planning air for a pressure blast pot. Target pressure is 80 PSI with a #4 (1/4") nozzle while I strip paint on welded fabrications. Current compressor is rated…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 15 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 4 Apr · asked in CFM and air
Answered

What PSI should I run to clean weld scale on farm equipment without warping thin metal in a small shop?

Thin farm equipment panels warp when I blast hard. Media is silicon carbide, nozzle is #4 (1/4"). Need a safer pressure window for coating with zinc-rich primer. Looking…

CFM and air

Top answer

On thin farm equipment, begin near the low end of 80 PSI and increase only until you clean weld scale cleanly. Hot spots and long dwell times warp…

0 found this helpful 1 answer
Answer
Admin 3 Apr · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 422)?

Pot holds pressure at rest, then falls once I pull the trigger on stainless steel. Setup uses a #4 (1/4") nozzle and a compressor advertised at 50 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 50 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 2 Apr · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 416)?

Planning air for a contractor pot. Target pressure is 80 PSI with a #4 (1/4") nozzle while I prep for powder coat on alloy wheels. Current compressor is…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 100 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 31 Mar · asked in CFM and air
Answered

What PSI should I run to strip paint on steel tanks without warping thin metal in a small shop?

Thin steel tanks panels warp when I blast hard. Media is aluminum oxide, nozzle is #4 (1/4"). Need a safer pressure window for coating with powder coat. Looking…

CFM and air

Top answer

On thin steel tanks, begin near the low end of 80 PSI and increase only until you strip paint cleanly. Hot spots and long dwell times warp panels…

0 found this helpful 1 answer
Answer
Admin 30 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 404)?

Pot holds pressure at rest, then falls once I pull the trigger on cast iron. Setup uses a #4 (1/4") nozzle and a compressor advertised at 25 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 25 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 29 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 398)?

Planning air for a vacuum blast unit. Target pressure is 80 PSI with a #4 (1/4") nozzle while I peen for fatigue life on exhaust manifolds. Current compressor…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 50 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 28 Mar · asked in CFM and air
Answered

What PSI should I run to prep for powder coat on sheet metal panels without warping thin metal in a small shop?

Thin sheet metal panels panels warp when I blast hard. Media is silicon carbide, nozzle is #4 (1/4"). Need a safer pressure window for coating with clear coat.…

CFM and air

Top answer

On thin sheet metal panels, begin near the low end of 80 PSI and increase only until you prep for powder coat cleanly. Hot spots and long dwell…

0 found this helpful 1 answer
Answer
Admin 26 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 386)?

Pot holds pressure at rest, then falls once I pull the trigger on automotive frames. Setup uses a #4 (1/4") nozzle and a compressor advertised at 15 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 15 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 25 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 380)?

Planning air for a blast room. Target pressure is 80 PSI with a #4 (1/4") nozzle while I clean weld scale on structural beams. Current compressor is rated…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 25 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 24 Mar · asked in CFM and air
Answered

What PSI should I run to peen for fatigue life on welded fabrications without warping thin metal in a small shop?

Thin welded fabrications panels warp when I blast hard. Media is aluminum oxide, nozzle is #4 (1/4"). Need a safer pressure window for coating with paint strip. Looking…

CFM and air

Top answer

On thin welded fabrications, begin near the low end of 80 PSI and increase only until you peen for fatigue life cleanly. Hot spots and long dwell times…

0 found this helpful 1 answer
Answer
Admin 23 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 368)?

Pot holds pressure at rest, then falls once I pull the trigger on farm equipment. Setup uses a #4 (1/4") nozzle and a compressor advertised at 100 CFM.…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 100 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 21 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 362)?

Planning air for a pressure blast pot. Target pressure is 80 PSI with a #4 (1/4") nozzle while I strip paint on stainless steel. Current compressor is rated…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 15 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 20 Mar · asked in CFM and air
Answered

What PSI should I run to clean weld scale on alloy wheels without warping thin metal in a small shop?

Thin alloy wheels panels warp when I blast hard. Media is silicon carbide, nozzle is #4 (1/4"). Need a safer pressure window for coating with zinc-rich primer.

CFM and air

Top answer

On thin alloy wheels, begin near the low end of 80 PSI and increase only until you clean weld scale cleanly. Hot spots and long dwell times warp…

0 found this helpful 1 answer
Answer
Admin 19 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 350)?

Pot holds pressure at rest, then falls once I pull the trigger on steel tanks. Setup uses a #4 (1/4") nozzle and a compressor advertised at 50 CFM.

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 50 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 18 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 344)?

Planning air for a contractor pot. Target pressure is 80 PSI with a #4 (1/4") nozzle while I prep for powder coat on cast iron. Current compressor is…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 100 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 16 Mar · asked in CFM and air
Answered

What PSI should I run to strip paint on exhaust manifolds without warping thin metal in a small shop?

Thin exhaust manifolds panels warp when I blast hard. Media is aluminum oxide, nozzle is #4 (1/4"). Need a safer pressure window for coating with powder coat.

CFM and air

Top answer

On thin exhaust manifolds, begin near the low end of 80 PSI and increase only until you strip paint cleanly. Hot spots and long dwell times warp panels…

0 found this helpful 1 answer
Answer
Admin 15 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 332)?

Pot holds pressure at rest, then falls once I pull the trigger on sheet metal panels. Setup uses a #4 (1/4") nozzle and a compressor advertised at 25…

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 25 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 14 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 326)?

Planning air for a vacuum blast unit. Target pressure is 80 PSI with a #4 (1/4") nozzle while I peen for fatigue life on automotive frames. Current compressor…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 50 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 13 Mar · asked in CFM and air
Answered

What PSI should I run to prep for powder coat on structural beams without warping thin metal in a small shop?

Thin structural beams panels warp when I blast hard. Media is silicon carbide, nozzle is #4 (1/4"). Need a safer pressure window for coating with clear coat.

CFM and air

Top answer

On thin structural beams, begin near the low end of 80 PSI and increase only until you prep for powder coat cleanly. Hot spots and long dwell times…

0 found this helpful 1 answer
Answer
Admin 11 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 314)?

Pot holds pressure at rest, then falls once I pull the trigger on welded fabrications. Setup uses a #4 (1/4") nozzle and a compressor advertised at 15 CFM.

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 15 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 10 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 308)?

Planning air for a blast room. Target pressure is 80 PSI with a #4 (1/4") nozzle while I clean weld scale on farm equipment. Current compressor is rated…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 25 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 9 Mar · asked in CFM and air
Answered

What PSI should I run to peen for fatigue life on stainless steel without warping thin metal in a small shop?

Thin stainless steel panels warp when I blast hard. Media is aluminum oxide, nozzle is #4 (1/4"). Need a safer pressure window for coating with paint strip.

CFM and air

Top answer

On thin stainless steel, begin near the low end of 80 PSI and increase only until you peen for fatigue life cleanly. Hot spots and long dwell times…

0 found this helpful 1 answer
Answer
Admin 8 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 296)?

Pot holds pressure at rest, then falls once I pull the trigger on alloy wheels. Setup uses a #4 (1/4") nozzle and a compressor advertised at 100 CFM.

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 100 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 6 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 290)?

Planning air for a pressure blast pot. Target pressure is 80 PSI with a #4 (1/4") nozzle while I strip paint on steel tanks. Current compressor is rated…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 15 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 5 Mar · asked in CFM and air
Answered

What PSI should I run to clean weld scale on cast iron without warping thin metal in a small shop?

Thin cast iron panels warp when I blast hard. Media is silicon carbide, nozzle is #4 (1/4"). Need a safer pressure window for coating with zinc-rich primer.

CFM and air

Top answer

On thin cast iron, begin near the low end of 80 PSI and increase only until you clean weld scale cleanly. Hot spots and long dwell times warp…

0 found this helpful 1 answer
Answer
Admin 4 Mar · asked in CFM and air
Answered

Why does my blast pressure drop below 80 PSI after a few minutes in a small shop (guide 278)?

Pot holds pressure at rest, then falls once I pull the trigger on exhaust manifolds. Setup uses a #4 (1/4") nozzle and a compressor advertised at 50 CFM.

CFM and air

Top answer

Pressure collapse after a few minutes usually means the compressor cannot sustain the nozzle demand. A #4 (1/4") at working pressure often exceeds a 50 CFM intermittent rating.Check…

0 found this helpful 1 answer
Answer
Admin 3 Mar · asked in CFM and air
Answered

How much CFM do I need for a #4 (1/4″) nozzle at 80 PSI in a small shop (guide 272)?

Planning air for a contractor pot. Target pressure is 80 PSI with a #4 (1/4") nozzle while I prep for powder coat on sheet metal panels. Current compressor…

CFM and air

Top answer

A #4 (1/4") nozzle at 80 PSI typically needs more continuous CFM than intermittent tool ratings suggest. Treat 100 CFM as a starting estimate and size for duty…

0 found this helpful 1 answer
Answer
Admin 1 Mar · asked in CFM and air
Answered

What PSI should I run to strip paint on automotive frames without warping thin metal in a small shop?

Thin automotive frames panels warp when I blast hard. Media is aluminum oxide, nozzle is #4 (1/4"). Need a safer pressure window for coating with powder coat.

CFM and air

Top answer

On thin automotive frames, begin near the low end of 80 PSI and increase only until you strip paint cleanly. Hot spots and long dwell times warp panels…

0 found this helpful 1 answer
Answer
Post